- Home
- Search Results
- Page 1 of 1
Search for: All records
-
Total Resources1
- Resource Type
-
0000000001000000
- More
- Availability
-
10
- Author / Contributor
- Filter by Author / Creator
-
-
Ashkhasi, Ali (1)
-
Eriksson, Stefan (1)
-
Gibble, Kurt (1)
-
Hangst, Jeffrey (1)
-
Hendricks, R_J (1)
-
Madsen, Niels (1)
-
Marshall, Virginia_Rose (1)
-
Nauta, Janko (1)
-
Oliveira, Alvaro_Nunes (1)
-
Rasmussen, Chris_Ørum (1)
-
Schoonwater, Joos (1)
-
Szymaniec, Krzysztof (1)
-
Thorpe-Woods, Edward (1)
-
Whale, Josh (1)
-
Wilson, Andrew (1)
-
#Tyler Phillips, Kenneth E. (0)
-
#Willis, Ciara (0)
-
& Abreu-Ramos, E. D. (0)
-
& Abramson, C. I. (0)
-
& Abreu-Ramos, E. D. (0)
-
- Filter by Editor
-
-
& Spizer, S. M. (0)
-
& . Spizer, S. (0)
-
& Ahn, J. (0)
-
& Bateiha, S. (0)
-
& Bosch, N. (0)
-
& Brennan K. (0)
-
& Brennan, K. (0)
-
& Chen, B. (0)
-
& Chen, Bodong (0)
-
& Drown, S. (0)
-
& Ferretti, F. (0)
-
& Higgins, A. (0)
-
& J. Peters (0)
-
& Kali, Y. (0)
-
& Ruiz-Arias, P.M. (0)
-
& S. Spitzer (0)
-
& Sahin. I. (0)
-
& Spitzer, S. (0)
-
& Spitzer, S.M. (0)
-
(submitted - in Review for IEEE ICASSP-2024) (0)
-
-
Have feedback or suggestions for a way to improve these results?
!
Note: When clicking on a Digital Object Identifier (DOI) number, you will be taken to an external site maintained by the publisher.
Some full text articles may not yet be available without a charge during the embargo (administrative interval).
What is a DOI Number?
Some links on this page may take you to non-federal websites. Their policies may differ from this site.
-
Abstract The performance of a caesium fountain frequency reference for use in precision measurements of trapped antihydrogen in the ALPHA experiment at CERN is evaluated. A description of the fountain is provided together with a characterisation of systematic effects. The impact of the magnetic environment in the Antimatter Factory, where the fountain is installed, on the performance of the fountain is considered and shown to be insignificant. The systematic fractional frequency uncertainty of the fountain is 3.0 × 10-16. The short-term frequency stability of the measured frequency from the ALPHA-HM1 maser is 1.5 × 10-13τ-1/2, whereas the fountain itself shows a stability limit of 4.7 × 10-14τ-1/2. We find a fractional frequency difference of (1.0 ± 2.2 (stat.) ± 6.5 (syst.)) × 10-16 in a comparison with Terrestrial Time via a GNSS Common View satellite link between January 2023 and June 2024. The fountain will enables a significant increase in frequency precision in antihydrogen spectroscopic measurements, and paves the way for improved limits on matter-antimatter comparisons.more » « less
An official website of the United States government
